Page 89
WESMAR
INSTALLATION AND OPERATION
Adjust RV4 TVG Offset to + 0.02 VDC (slightly positive).
3.0
TRANSMITTER, PREAMP,
RECEIVER
ADJUSTMENT
(J-Box)
Locate a solid target 100-200 meters, (300-600 feet) away.
Select the smallest scanning sector and position the sector
over the target with the Bearing Knob. Adjust Tilt, Bearing,
Near and Far Gain for
Sonar A
for good target marking on
the display.
Connect the positive lead of an Analog Volt OHM Meter
(VOM) to TP5, Receiver Output (see T.P.R. drawing for loca-
tion). Connect the negative lead to TP1, Receiver Ground.
Select the 3 Volt DC scale on the VOM. The DC scale will
give better results than the AC scale.
Adjust the following, in order, for maximum defl ection on
the VOM. To verify your tuning, repeat the procedure.
1.
T1 Transmitter
2.
L1 Preamp
3.
L2 Preamp
4.
L3 Preamp
5.
T5 Receiver
6.
L4 Receiver
7.
L5 Receiver
Note:
Adjustment must be made with a nonmagnetic tool.
4.0
RECEIVER GAIN ADJUSTMENT
(CONSOLE)
Use the front panel Function Knob, and for
Sonar A
set:
Speed
-
1
Pulse width -
0 (zero) percent
TVG
-
0
Threshold -
3
Set Near Gain,
Sonar A
, to 100 (maximum).
Set Far Gain,
Sonar A
, to 75.
Содержание HD800/110-10
Страница 10: ...Page 10 WESMAR HD800...
Страница 32: ...Page 32 WESMAR HD800 Section III INSTALLATION...
Страница 64: ...Page 64 WESMAR HD800 HYDRAULIC HOIST ASSEMBLY A...
Страница 65: ...Page 65 WESMAR INSTALLATION AND OPERATION HYDRAULIC HOIST ASSEMBLY B...
Страница 74: ...Page 74 WESMAR HD800 M18 HOIST CONTROL CIRCUITRY THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 86: ...Page 86 WESMAR HD800...
Страница 87: ...Page 87 WESMAR INSTALLATION AND OPERATION Section IV FIELD ADJUSTMENTS CALIBRATION...
Страница 92: ...Page 92 WESMAR HD800 HD J BOX TRANSMIT PREAMP RECEIVER PCB T P R...
Страница 98: ...Page 98 WESMAR HD800 FT Hydraulic Assembly...