10
English
9) Min time
It is possible to set a time range. Within this range, the
screw is OK. Minimum time is 0 second (OFF).
Use:
- Press
OK
on Min Time
- Select through
UP/DOWN
buttons.
- Press
OK
to confirm or
ESC
to quit without saving
10) Max time
It is possible to set max time from Min time + 0.1 second
to 10.0 seconds. Over the max time, screwdriver will be
automatically stopped.
Use:
- Press
OK
on Max Time
- Select through
UP/DOWN
buttons.
- Press
OK
to confirm or
ESC
to quit without saving
11) Password set
It is possible to set a password of 4 digits. The password is
required to enter the menu anytime you switch on the unit.
Without the password, it is not possible to change any
parameter. With clutch model, the operator can modify the
torque (it is mechanically set in the screwdriver), but with
ECL model no parameters can be changed.
Default password is ‘
0000
’.
Use:
- Press
OK
on Password Set
- Set through
UP/DOWN
the digit
- Press
OK
to confirm.
- Repeat for all the digits.
12) Password On
It is possible to choose if the password may or may not be
required.
Use:
- Press
OK on
PASSW ON
- Select through
UP/DOWN
buttons.
- Press
OK
to confirm,
ESC
to quit without saving
13) Language
To select between 3 languages: English, German and
Italian.
Use:
- Press
OK
on Language
- Select through
UP/DOWN
buttons.
- Press
OK
to confirm,
ESC
to quit without saving
OTHER FUNCTION:
Display backlight: to reduce the consumption of unit, over
60 second after last operation backlight will be turn OFF. To
active again you may press a taste (
OK, ESC, UP, DOWN
) or
LEVER on screw driver or external command on the rear of
unit.
ECL model calibration:
The ECL model requires a calibration.
Screwdriver with clutch doesn’t need it.
For any details, see the WBTS instructions manual.
ATTENTION:
The process required that the screw driver is free of load,
don’t connect something, take the screw driver free on
hair.
If you connect for first time a ECL model to unit is
necessary to do this procedure.
- Turn
ON
unit and set ECL model to point 1) of menu
(see chapter Menu for more details)
- Now set torque to LOW to point 3) and press
OK
to save
(see chapter Menu for more details),
be attention to set point 4) to soft, hard mode don’t
accept Torque range
- Turn
OFF
instruments
- Press lever and hold. With lever press turn
ON
unit
after 1 second system automatically calibrate unit with
screw driver.
- Now repeated process but with Torque range set
High
.
- Calibration is finished
9 ) M I N T M : 0 , 0 s
1 0 ) M A X T M : 1 0 , 0 s
9 ) M I N T M : 0 , 0 s
1 0 ) M A X T M : 1 0 , 0 s
1 1 ) P A S S W O R D S E T
1 2 ) P A S S W O N : Y E S
1 1 ) P A S S W O R D S E T
1 2 ) P A S S W O N : Y E S
1 3 ) L A N G U A G E : E N