4 Module descriptions
| Digital input and output modules IP67, PROFIBUS, 60 mm, metal housing
19
2484950000/00/03.2016
Manual UR67-PROIFBUS
PROFIBUS address
You can set the module's PROFIBUS address either using the
rotary switches or via the PROFIBUS-DP network. A value
between 1 and 126 is possible (default 126). If an address
>126 has been set with the rotary switches, the address will
be automatically be set to 126.
The address set will be adopted during switching
on the power supply. For a change the power sup-
ply has to be interrupted temporarily.
Setting the address manually
IN
OUT
4
8
BF DIA
ACT
U
S
A
DIA
B
x100
x1
x10
0 1
2
3
4
5
6
7
8
9
0 1
2
3
4
5
6
7
8
9
0 1
2
3
4
5
6
7
8
9
0 1
2
3
4
5
6
7
8
9
0 1
2
3
4
5
6
7
8
9
0 1
2
3
4
5
6
7
8
9
BUS
Rotary switches on the module
▶
Set the address with the rotary switches (hundred left,
decade middle, unit position right).
The address set will be adopted during the next switch-on of
the power supply.
Changing the address
▶
Set the new address as described above.
▶
Interrupt the power supply temporarily.
The new address set will be adopted during the next switch-
on of the power supply.
Setting the address via the network
Prior to this you have to set the rotary switches to "000".
This setting may not be changed during operation. You will
find a detailed description in the manual of your respective
PROFIBUS-DP-master.
Data transfer rate
The data transfer rate will be detected and set automatically
as soon as the module communicates with the master (auto
baud detection).