The profile rail (UR) is displayed with the open positions.
Profile rail with open positions
Selecting the control unit version
▶
Click on the second line of the
UR
table.
▶
From the catalogue, select the control unit in use and its
version (inscription on the control unit, e.g. 314-GEH04-
...).
Selecting the control unit version
▶
Double-click on the respective version, or use the mouse
to drag it to the second position in the table on the left-
hand side of the window.
The
Properties Ethernet interface
window opens.
Ethernet interface properties
▶
Enter the designated IP address and the subnet mask.
▶
Confirm with
OK
.
Adding a PROFIBUS network
▶
Double-click on the MPI/DP interface to create the
PROFIBUS network.
The
MPI/DP properties
window opens.
Properties MPI/DP
▶
Choose “
Profibus
” as interface type.
7 Commissioning
| Commissioning the UR67 module
39
2484950000/00/03.2016
Manual UR67-PROIFBUS