2.1 Rating Definitions
Rating definitions
Running conditions
COP
Continuous power
Engines of this rating provide unlimited hours of
usage in a constant 100% load.
No overload capability is allowed.
PRP
Unlimited Prime Rated Power
Engines of this rating provide unlimited hours of
usage in a variable load application.
The average load factor should not exceed 70% of
the engine’s prime power rating for each 250 hours
duration; with a maximum number of 500
operational hours at 100% prime power rating.
An overload capability of 10% is available, however,
is limited to a period of 1 in every 12 hours.