Appendix
82
Grouping
SFC
Description
FMI SPN
Minor Alarm
256
Minor alarm hardware Fault
5
5078
O2 PostCat
181
Postcat O2 Voltage High
3
3227
182
PostCat O2 Voltage Low
4
3227
186
PostCat O2 Failed on Lean Side
17
3227
185
PostCat O2 Failed on Rich Side
15
3227
187
PostCat O2 Heater Short Open Fault
5
3227
O2 PreCat
184
PreCat O2 inactive fault
8
3217
197
PreCat O2 Failed on Lean Side
17
3217
189
PreCat O2 Failed on Rich Side
15
3217
225
PreCat O2 input high
3
3217
226
PreCat O2 input Low
4
3217
183
PreCcat O2 Heater Short Open Fault
5
3217
Oil Pressure
192
Oil Pressure Voltage High
3
100
191
Oil Pressure Voltage Low
4
100
195
Oil Pressure Low
1
100
196
Oil Pressure Fault
15
100
Oil Temperature
194
Oil Temperature Voltage High
3
175
193
Oil Temperature Voltage Low
4
175
222
Oil Temperature High
16
175
198
Oil Temperature IR Low
17
175
Synchronization Input
812
Synchronizer input high
3
3938
813
Synchronizer input low
4
3938
Remote Reference
638
Remote Speed reference input high
3
189
639
Remote Speed reference input low
4
189
Power Supplies
165
Battery Voltage Higher Than Expected
0
168
166
Battery Voltage Lower Than Expected
1
168
169
DRVP Higher than Expected
20
168
161
XDRP (+5V) Voltage HTE
3
3509
162
XDRP (+5V) Voltage LTE
4
3509
L series / F series Throttle
Valve
541
L Series / F Series Throttle Position
Voltage High
3
51
542
L Series / F Series Throttle Position
Voltage Low
4
51
557
L Series Throttle Status
12
51
556
L Series Throttle fault
5
51
558
TPS Data Drift High
0
51
559
TPS Data Drift Low
1
51
544
Throttle Position adapt low fault
18
51
637
Throttle Position adapt high fault
16
51