Installation
40
3.9 Engine Electronic System
3.9.1 Starter Circuit
Wire size of starter main cable:
≥
70mm
2
;
Wire size of ground wire:
≥
70mm
2
;
Wire size of starter controlling cable:
≥
1.5mm
2
;
The wiring terminals of starter shall be equipped
with protective caps;
Summation of startup cables' resistance (terminals
No. 30 and 31):
≤
1mΩ;
Permissible voltage decrease of main cable:
≤
0.17V/100A;
Before installing, remove the paint on the connecting
points.
For the starter, the rated voltage is 24V, rated power
is 10 kW.
Figure 3.9.1- Starter wiring diagram