0
Trigger activation position
Wiring connections
•
Insert a 2mm Allen key into the activation position
set screw
.
•
To move the activation point closer towards the start
of the trigger pull turn the set screw
clockwise
.
•
To move the activation point closer towards the
end of the trigger pull turn the set screw
counter
clockwise
.
•
Ensure that the Angel is de-gassed and switched off.
•
Remove the right hand side grip cheek cover by
removing the 3 retaining screws using a suitable
2mm Allen key.
•
Access to the PCB and its wiring connections
is now gained.
Important notes for re assembly of components.
•
Do not trap any wiring or damage could occur
to the wiring resulting in a fault developing.
•
Do not pull the plugs out from the PCB by the
wiring always use a suitable tool to extract the
plug from its socket.
ADHERE STRICTLY TO THESE
AND ALL OTHER SAFETY
INSTRUCTIONS AND GUIDELINES
· Ensure a barrel blocking device is fitted
to the ANGEL.
· Ensure the hopper is removed from
the ANGEL.
· Ensure that there are no paintballs
in the ANGEL.
· Always remove the first stage regulator and
release all residual gas pressure from the
Angel before disassembly.
· The Angel can hold a small residual gas
charge, typically two shots, with the first stage
regulator removed. Always discharge the Angel
in a safe direction to relieve this residual gas
pressure.
· NEVER adjust your trigger so fine that
accidental discharge can occur due to shock
loads or vibration.
· SHOULD YOU BE UNSURE AT ANY STAGE YOU
MUST SEEK EXPERT ADVICE.
NOTE: WHEN RECONNECTING THE EYE RIBBONS
TO THE PCB THE SHORTER RIBBON CONNECTS