ADHERE STRICTLY TO THESE
AND ALL OTHER SAFETY
INSTRUCTIONS AND GUIDELINES
· Ensure a barrel blocking device is fitted
to the ANGEL.
· Ensure the hopper is removed from
the ANGEL.
· Ensure that there are no paintballs
in the ANGEL.
· Always remove the first stage regulator and
release all residual gas pressure from the
Angel before disassembly.
· The Angel can hold a small residual gas
charge, typically two shots, with the first stage
regulator removed. Always discharge the Angel
in a safe direction to relieve this residual gas
pressure.
· NEVER adjust your trigger so fine that
accidental discharge can occur due to shock
loads or vibration.
· SHOULD YOU BE UNSURE AT ANY STAGE YOU
MUST SEEK EXPERT ADVICE.
Exhaust valve stem removal
Exhaust valve guide removal
•
Remove the mini reg spool
as per the in line
regulator service instructions (see page 20).
•
Remove the fore grip body internal retaining
screw
using a 4mm Allen key and the
fore grip itself
.
•
Ensure that the fore grip body seal
is not lost.
•
Extract shear pin
by inserting the M3
extraction tool (supplied) into the threaded end
of the shear pin.
•
Remove the volume chamber maintenance plug
and eye ribbon cover
(see page 22).
•
Remove the volume chamber plug
being
careful not to damage the end plug seal.
•
Remove the exhaust valve stem
.
•
Remove the grip cheek cover
by removing the 3
retaining screws using a metric 2mm Allen key.
•
Unplug the Angel eyes and solenoid plugs
(see page 22) from the circuit board.
•
Remove the 2 grip frame screws
0
holding the
frame to the body using a suitable 3mm Allen key.
•
Remove the grip frame
from the body.
•
Pull out the exhaust valve guide retaining pin
located in the body using suitable grips.
•
Using a suitable blunt hooked pick carefully retract
the exhaust valve guide
by inserting the pick
into the exhaust valve hole that the exhaust valve
stem located into.
•
Inspect and service parts as necessary.
0
0
The exhaust valve stem is a consumable item that will
eventually wear out. Premature failure of the exhaust
valve stem is caused by dirty air or failure to lubricate
it at service intervals, to replace the exhaust valve
stem follow the procedures listed below.
•
Remove the volume chamber valve
maintenance plug
.
•
Remove the valve stem assembly
.
Important notes for the re assembly of
components.
•
Ensure exhaust valve stem assembly is located
in the exhaust body within the Angel.
•
Ensure that the end cap is located correctly.