i
Shot % Filtering
feature by pushing the
navigation switch inward.
•
Scroll up or down through the
Shot % Filtering
settings by pushing the navigation switch up
or down.
•
Once the desired setting has been reached
press the navigation switch inwards to save
the new setting.
A
Saved Shot % Filtering
message will be
displayed.
The Parameters menu will be displayed.
Anti Bolt Stick
First shot drop off can occur when the valve or ram
incurs static friction after a period of inactivity, this
results in the first shots fired after this inactivity
being lower in velocity because the seals need to
break free from the forces of the static friction.
Anti Bolt stick programming allows the dwell time
to be increased for the first 2 shots if the Angel had
been inactive for 15 seconds to overcome static
friction. There are 20 levels of ABS adjustment
ranging from 0.25 milliseconds to 5 milliseconds.
•
Ensure that the Angel is switched on.
•
Ensure that you are not activating the trigger.
•
Push and hold the navigation switch UP or DOWN
for 1.5 seconds.
•
The
Status
menu will be displayed.
•
Push the navigation button up to highlight the
i
Parameters
menu.
•
Push the navigation switch in to select the
Parameters
menu.
•
From the
Parameters
menu select the
i
Anti Bolt Stick
feature by pushing the
navigation switch inwards.
•
Scroll up or down through the
Anti Bolt Stick
settings by pushing the navigation switch up
or down.
•
Once the desired setting has been reached
press the navigation switch inwards to save
the new setting.
A
Saved Anti Bolt Stick
message will be displayed
The
Parameters
menu will be displayed.
ADHERE STRICTLY TO THESE
AND ALL OTHER SAFETY
INSTRUCTIONS AND GUIDELINES
· Ensure a barrel blocking device is fitted to
the ANGEL.
· Ensure the hopper is removed from the
ANGEL.
· Ensure that there are no paintballs in the
ANGEL.
· SHOULD YOU BE UNSURE AT ANY STAGE YOU
MUST SEEK EXPERT ADVICE.
Parameters - Anti bolt stick
Software version
The software version is displayed on the
information page.
•
With the Angel on and
Live
push the navigation
switch up or down for 1.5 seconds.
•
The Angel will be in the
Status
menu .
•
Use the navigation switch to scroll through
the Status menu settings till
Information
is highlighted.
Push the navigation switch inward to select the
Information
menu.
Factory reset
The default factory settings can be restored if
required at any time.
•
Press the internal button located on the circuit
board inside the grip frame.
•
The screen will display the internal options menu
•
Using the navigation switch scroll up or down
to select the reset function.
•
Press the navigation switch inward to initiate
the reset function.
•
You will be asked to confirm that you wish to
continue with this action. Press the navigation
button inward to confirm this is correct.
•
A reset message will be displayed on the
screen confirming that the default settings have
successfully been restored.
Software version - Factory reset