Adapta Valve Installation
Turn off the cold water supply to the faucet by turning the angle stop valve
completely off.
Reverse Osmosis Module Mounting
Step 13
Determine best location for the RO module to be mounted to allow for
future system maintenance. The parts bag has 2 self tapping screws.
Using a phillips screwdriver, screw them into the cabinet wall 10 ¾”
apart and 16" from the bottom of the cabinet.
Step 11
Step 12
Attach adapta valve as illustrated in the three photos above, choosing the
configuration that fits your plumbing. (When attaching the adapta valve to
straight pipe threads, use Teflon tape on the treads.) The green tube from inlet side of RO
module will be cut to length and attached later in the installation.
Do not cut these tubes at this time
Note:
Caution:
Watersupply line to the system must be from the cold water supply line. Hot water will
severely damage your system.
Configuration for 3/8”
compression fittings
Configuration for 1/2”
compression fittings