Page 16
To be properly seated the tip of the Membrane must be below the
housing edge.
After replacing membrane housing into clips, attach the green tube to
the elbow on cap using 5/8" wrench.
The flow restrictor must be changed each time you change the
Membrane. Replace the existing flow restrictor with the new one by
removing the White Compression Nuts. Be sure to orientate the Flow
with the arrow pointing toward the faucet.
Step 8
Step 9
Tip of Membrane
Edge of Housing
Note:
Step 10
Follow the Start Up Instructions.
Check air pressure when tank is empty!
Check Air Pressure in the Tank
Using a digital air gauge check the air pressure in the tank. You should
always have between 5 -7 psi. If you have more than 7 psi release air
and recheck. If you have less than 5 psi, add air. Air can be added with
a bicycle pump.
Your unit comes with a stand for your storage tank to sit on if you need
to turn the unit on its side.
This allows for air flow under the tank keeping moisture and standing
water from rusting on the bottom of your tank which would void your
warranty.