Page 20
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVALS:
Note: Depending on incoming feed water conditions replacement time frame may vary.
Description
Change time Frame
Price
Sediment Pre-filter: #5m-10
6 Months
$4.50
Carbon Pre-filter:
#GAC-410-56/#5MCB
6 Months
$9.00/10.50
Final Carbon filter
#1m-6/#1M-10
12 Months
$9.00/11.95
R.O. Membrane:
#TFM-24
2 to 5 years
$82.95
This system has been tested according to NSF/ANSI 58 for reduction of the substances below. The concentration of the indicated substances in water
entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI 58.
This system has been tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or arsenate) at concentrations
of 0.30 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water
supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent
arsenic. Treatment with chloramine (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic,
Please see the Arsenic Facts section of the Performance Data Sheet for further information.
Avg. In.
Avg. Eff.
% Reduction pH
P r e s s u r e
Max Eff.
Inf. challenge
Max Allowable
concentration
concentration
mg/L
mg/L
Arsenic (Pentavalent) 334.615 ug/L
5.0385 ug/L
98.4%
50psi
19 ug/L
0.30±10%
0.010 mg/L
Barium Reduction
10.2 mg/L
0.207 mg/L
97.9%
7.24
50psi
0.3 mg/L
10.0±10%
2.0
Cadmium Reduction
0.036 mg/L
0.0005 mg/L
98.6%
7.49
50psi
0.0007
0.03±10%
0005
Chromium (Hexavalent) 0.15 mg/L
0.013 mg/L
91.3%
7.24
50psi
0.03
0.03±10%
0.1
Chromium (Trivalent)
0.17 mg/L
.01 mg/L
94.1%
7.24
50psi
0.01
0.03±10%
0.1
Copper Reduction
3.1 mg/L
0.03 mg/L
99.0%
7.64
50psi
0.04
3.0±10%
1.3
Cysts
222,077#/ml
10 #/ml
99.99%
5 8 minimum 50,000/mL
Fluoride Reduction
8.0 mg/L
0.5 mg/L
93.9%
7.49
50psi
0.7
8.0±10%
1.5
Lead Reduction
0.15 mg/L
0.002 mg/L
98.6%
7.49
50psi
0.003
0.15±10%
0.010
Radium 226/228
25pCi/L
5pCi/L
80.0%
7.24
50psi
5pCi/L
25pCiL±10%
5pCiL
Selenium
0.10
0.008
92.0%
50psi
0.011
0.10±10%
0.05
TDS
96.8%
7.84
750±40mg/L
187
Turbidity
10.2 mg/L
0.26 mg/L
97.5%
0.83
11±1 NTU
0.5 NTU
Note: Depending on water chemistry, water temperature, and water pressure Watts Premier’s R.O. Systems production and performance will vary.
Efficiency rating means the percentage of the total water required to operate the system that is treated and available to the user.
REFER TO OWNER’S INSTALLATION/SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY INFORMATION.
Phone: (623) 931-1977
Fax: (623) 931-0191
Email: [email protected]
GENERAL USE CONDITIONS:
1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. DO NOT use with
water that is microbiologically unsafe or unknown quality without adequate disinfection before and after the system. Systems certified for cyst
reduction may be used on disinfected water that may contain filterable cysts.
2. Operating Temperature:
Maximum: 100°F (40.5°C)
Minimum: 40° (4.4°)
3. Operating Water Pressure:
Maximum: 100 psi (7.0kg/cm2)
Minimum: 40 psi (2.8kg/cm2)
4. pH
3 to 11
5. No iron present in incoming feed water supply.
6. Hardness of more than 7 grains per gallon (120 ppm) may reduce TFM membrane life expectancy.
7. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.
Model No.
Avg.
Avg.
Avg. TDS DPR
I n f l u e n t
Effluent
IN /EFF
RECOVERY
GALLONS
EFFICIENCY
TDS
TDS
REDUCTION
765 mg/l
23mg/l
96.8%
15.5%
9.06gpd
8.35%
Watts Premier Inc.
1725 W. Williams Drive C-20
Phoenix, AZ 85027 USA
California Certification # 00-1452
Watts Premier Product Data Sheet
5 SV Deluxe, CRO-TFM-5SV, Ultra 5 and Pur-Tek, Watts 25, Watts RO-4, Watts RO-5, RO-TFM-4SV, RO-TFM-
Содержание 5 SV DELUXE
Страница 19: ...Page 19 California Certification...
Страница 24: ...Page 24...