page 39 of 42
The stove is clogged
early in the brazier with
burning irregular, door
glass gets dirty, the
flame is long, reddish
and weak
1.
Flue with presence of stretches
too long or clogged
2.
Too pellet
3.
Excessive pellet or ash deposits
in the brazier
4.
The brazier is not found in its
slot
5.
Wind contrary to the exhaust
flow
6.
Insufficient combustion air
7.
You changed the type of pellets
used
8.
Smoke extractor motor broken
9.
Door closed incorrectly
1.
Perform periodic cleaning. See paragraph stove in-
stallation in the user manual. Check chimney cleaning
2.
Decrease in the parameters the charge level of the
pellets
3.
Clean the brazier after waiting for the total shut-
down of the stove.
If you repeat contact your Au-
thorized Service Center
4.
Check that the hole in the brazier matches the glow
plug
5.
Check the chimney cap windproof and / or possibly
install it
6.
Check the correct position of the brazier, its cleanli-
ness and check that the air intake in both free environ-
ment, verify the status of the door seal, increase the
level in the parameter relative to the speed of the fan
exhaust fumes.
Contact your Authorized Service
Center
7.
Check the quality of the pellets.
Contact your Au-
thorized Service Center
8.
Increase the level in the parameters relating to the
speed of the fan exhaust fumes.
Check and eventu-
ally replace motor
9.
Check that the glass is sealed and the seal guaran-
tees tightness
Smell of smoke in the
environment. Turning
off the stove.
1.
Poor combustion
2.
Malfunction of fan fumes
3.
Installation of the flue per-
formed incorrectly
4.
Clogged chimney
1. Contact your Authorized Service Center
2. Contact your Authorized Service Center
3. Contact your Authorized Service Center
4. Contact your Authorized Service Center
In the automatic posi-
tion the stove always
runs at full power
1.
Room thermostat set to maxi-
mum
2.
Significant temperature sensor
failure
3.
Control panel defective or
broken
1.
Reset the thermostat temperature
2.
Check the operation of the sensor and replace if
necessary
3.
Check the control panel and replace if necessary
The engine smoke ex-
traction does not work
1.
The stove has no voltage
2.
The motor is broken
3.
The board is defective
4.
The control panel has failed
1.
Check the supply voltage and the protection fuse.
2.
Check the motor and capacitor and replace if neces-
sary.
3.
Replace the circuit board.
4.
Replace the control panel.
EN
Содержание MIGNON6
Страница 1: ...MANUAL DE INSTRUCCIONES ESTUFAS DE PELLET ES...
Страница 4: ......
Страница 47: ...43 44 ES...
Страница 48: ...43 44 NOTAS ES...
Страница 49: ...44 44 NOTAS ES...
Страница 50: ...Cod 001120 Date 06 2021 ES NOTAS 45 44...
Страница 51: ...44 44...
Страница 52: ......
Страница 95: ...Cod 001120 Date Mar2021 EN NOTES page 42 of 42...
Страница 96: ...Cod 001120 Date 06 2021 NOTES page 43 of 42...
Страница 97: ...1 42...