page 19 of 42
Alarms signal
In the event of a working defect, the system
informs the user about the type of failure
occurred. The following table summarises
the alarms, kind of problem and possible
solution:
No acc
This alarm occurs when the time foreseen for
a light up (around 15 minutes) passes and the
smokes temperature is still too low. This can
occur also when there is not enough pellets fl
to light up the unit. Press the key On/Off on the
control board to reset the alarm. Wait until the
cooling phase is completed, clean the brazier
and start up with a new switching on.
No fire
This alarm occurs in the event the stove switches
off during its working phase (for example if there
is no pellets left in the pellets tank). You will
read the words “Alarm No fi e” on the display.
Press the key On/Off on the control board to
reset the alarm. Wait until the cooling phase is
completed, clean the brazier and start up with a
new switching on.
Cool fire
In the event of an even very short lack of current,
the stove switches off. As soon as the power
supply is back, the stove will start a cooling cycle
and the display will show the words “Cool fi e”.
After completing the cooling cycle, the stove
will start up again.
NOTE: If your stove is supplied with a remote
control and there is a lack of current, remember
to program the eventual switching on and off
times again. In the event of a lack of current, the
stove will loose any previous time settings.
Once the power supply is back, press the key
SEND on the remote control to retransmit
the automatic programming you previously
set to the stove.
Fan fail
This alarm occurs in the event the smokes ejector
is broken or the pcb cannot detect the speed of
the smokes exhaust fan. In this case press the
key On/Off to reset the alarm and contact the
technical assistance.
Dep Sic fail
This alarm is signalised by the Leds ALF and ALC
blinking on the control board.
It indicates two different possibilities: an
obstruction in the fl or a possible overheating
of the stove. In both cases the motor reducer
to load the endless screw stops working and
the stove switches off. Press the key On/Off to
reset the alarm. Check the possible activation of
the manual reset thermostat on the back of the
stove (4). Unscrew the safety cap and press the
key.
In the event you have the same problem
more than once, please contact the technical
assistance.
Sond fumi
This alarm occurs in the event the sensor for
smokes temperature is broken or not connected.
You will read the words Alarm Son fumi on the
display. In this case press the key On/Off to reset
the alarm and contact the technical assistance.
Serv
The signal “Serv” on the display means that
the stove has reached 1200 hours working.
Please contact an authorised technical service to
arrange a supplementary maintenance.
Regular checks should be carried out by the user, who should only contact the Authorized
Assistance Center if no solution is found.
EN
Содержание MIGNON6
Страница 1: ...MANUAL DE INSTRUCCIONES ESTUFAS DE PELLET ES...
Страница 4: ......
Страница 47: ...43 44 ES...
Страница 48: ...43 44 NOTAS ES...
Страница 49: ...44 44 NOTAS ES...
Страница 50: ...Cod 001120 Date 06 2021 ES NOTAS 45 44...
Страница 51: ...44 44...
Страница 52: ......
Страница 95: ...Cod 001120 Date Mar2021 EN NOTES page 42 of 42...
Страница 96: ...Cod 001120 Date 06 2021 NOTES page 43 of 42...
Страница 97: ...1 42...