page 7 of 42
EN
Flue
The following instructions have the purpose of
giving instructions on installation of a good flue,
however they do not replace in any way the
standards in force of which a qualified builder
must be aware. The stove manufacturer cannot
be held in any way liable in civil or criminal terms
for poor operation of the stove due to a wrongly
sized flue and/or non-compliance with legislation
in force, which must be complied with. The flue
must be built to standard and category ≥ T200 or
higher, with a vertical progression without choking,
resistant to condensate and resistant to fire caused
by soot. It must be externally insulated to avoid
smoke cooling and it must have a condensate
drain. If the flue is a cement shaft, it must be
ducted. The flue must be inspected for cleaning
and must also be distanced from flammable and/
or combustible materials.
The minimum distances to comply with from any
chimneys or reflux zones are outlined below.
Check the negative pressure between the flue
and the environment installed comply with the
instructions in the technical characteristics. The
minimum height of the flue is 3.5 metres and must
have an internal section that allows compliance
with these requirements and however not over
100mm. Check the correct configurations using
UNI EN 13384-1.
The flue must always be clean. Any soot residue
reduces the section of the flue which would
compromise draught and the soot could catch
fire. Have a professional chimney sweep clean
the flue and the chimney at least once a year and
before switching on the generator after periods of
inactivity. Lack of cleaning will negatively impact
correct operation of the equipment.
Chimney
The opening area for smoke evacuation must be at
least double the section of the flue and must prevent
snow and animals entering. The measurement of
the opening in the atmosphere must be outside
the backflow zone caused by the shape of the roof
and/or any obstacles found nearby. Pay attention
to the presence of skylights and dormer windows.
30° ROOF
45° ROOF
A = MIN. 1,30 metri
B = DISTANZA > 1,50 metri
C = DISTANZA < 1,50 metri
D = 0,50 metri OLTRE IL COLMO
E = 0,80 metri
F = BACKFLOW ZONE
FLAT ROOF
15° ROOF
A = MIN. 0,50 m
B = DISTANCE > 2,00 m
C = DISTANCE < 2,00 m
D = 0,50 metri
E = TECHNICAL VOLUME
A = MIN. 1,00 m
B = DISTANCE > 1,85 m
C = DISTANCE < 1,85 m
D = 0,50 m OVER THE RIDGE
E = 0,50 metri
F = BACKFLOW ZONE
60° ROOF
A = MIN. 2,00 m
B = DISTANZA > 1,30 metri
C = DISTANZA < 1,30 metri
D = 0,50 m OVER THE RIDGE
E = 1,50 metri
F = BACKFLOW ZONE
A = MIN. 2,60 m
B = DISTANZA > 1,20 m
C = DISTANZA < 1,20 m
D = 0,50 m OVER THE RIDGE
E = 2,10 m
F = BACKFLOW ZONE
Installation of the flue is not
permitted
equipment.
shared
with other
Содержание MIGNON6
Страница 1: ...MANUAL DE INSTRUCCIONES ESTUFAS DE PELLET ES...
Страница 4: ......
Страница 47: ...43 44 ES...
Страница 48: ...43 44 NOTAS ES...
Страница 49: ...44 44 NOTAS ES...
Страница 50: ...Cod 001120 Date 06 2021 ES NOTAS 45 44...
Страница 51: ...44 44...
Страница 52: ......
Страница 95: ...Cod 001120 Date Mar2021 EN NOTES page 42 of 42...
Страница 96: ...Cod 001120 Date 06 2021 NOTES page 43 of 42...
Страница 97: ...1 42...