CLS200 Series User’s Guide
Chapter 6: Ramp/Soak
128
3. Press the
NO
key. You will see the
RESET PROFILE
parameter. See
4. Press
YES
then
ENTER
to reset the profile. You will see the
ASSIGN PROFILE
parameter.
Assigning a Profile to a Loop on page 127
.
5. Choose one of the available profiles or
NONE
(to unassign) and press
ENTER
.
6. To return to the single loop display without changing the profile assignments, press
BACK
.
Running a Profile
When you assign a profile, it does not start running immediately. Instead, the loop is in the
START
mode and the
READY
segment (segment 0). Use the
SET MODE
parameter to start a profile (put it in
RUN
mode).
ALARM
01 ASSIGN R/S
PROFILE? A
Starting a Profile
You can start a profile only when it is in the
READY
segment.
1. In the single loop display, switch to the loop you want to start.
2. Press the
RAMP/SOAK
key three times. The
SET MODE
parameter appears.
3. Press
YES
and
ENTER
to start the profile. While the profile is in
START
mode, the only mode
available is the
RUN
mode.
Running Several Profiles Simultaneously
To run several profiles simultaneously, follow these steps:
1. Set up the profiles so that segment 1 of each profile has the same latched trigger.
2. Assign the profiles to the appropriate loops. The loops will go to the
READY
segment of
each profile.
3. Set each profile to
RUN
mode.
4. Trip the trigger.
Editing a Profile While It Is Running
You can edit a profile while it is running. Changes made to segments after the current segment will
take effect when the segment is reached. Changes made to the segments that have already been
completed will take effect the next time the profile is run. Do not edit the current segment. Changes
to the current segment can have unexpected consequences.
Holding a Profile or Continuing from Hold
Use the
SET MODE
parameter to select the ramp/soak profile mode.
Table 6.6
shows the
available modes.