Room Influence
LINE
FUNCTION
HC1
HC2
750
1050
Room influence
Control types:
When using a room temperature sensor there are 3
different types of control to choose from.
SETTING
CONTROL TYPE
- - - %
Simple control according to outdoor conditions *
1...99 %
Control according to outdoor conditions with room influence *
100 %
Control according to room temperature only
Requires the connection of an outdoor sensor
*
Simple control according to outdoor
conditions
The flow temperature is computed via the heating
curve according to the composite outdoor
temperature. This type of control requires proper
adjustment of the heating curve, as the control
does not take the room temperature into account
for this adjustment.
Control according to outdoor
conditions with room influence
The difference between the room temperature and
the setpoint value is measured and taken into
account for temperature control. This enables
taking into account possible heat inputs and
ensures a more accurate room temperature control.
The influence of the difference is defined as a
percentage. The better the installation in the
reference room (accurate room temperature,
correct installation location, etc.) the higher will be
the value that can be set.
Example:
Approx 60%: the reference room is appropriate
Approx 20%: the reference room is inappropriate
Information:
Activation of the function requires taking into
account the following requirements:
A room sensor must be connected.
-
The "room influence" parameter must be set
-
between 1 and 99.
The reference room (where the room sensor is
-
installed) must not contain adjusted thermostatic
valves. If present in the room, these valves must
be fully open.
Control according to
room temperature only
The flow temperature is adjusted according to the
room temperature setpoint, the current room
temperature and its evolution. A slight increase in
room temperature, for example, causes an
immediate drop in the flow temperature.
Information:
Activation of the function requires taking into
account the following requirements:
A room sensor must be connected.
-
The "room influence" parameter must be set
-
to 100%.
The reference room (where the room sensor is
installed) must not contain adjusted thermostatic
valves. If present in the room, these valves must be
fully open.
Содержание WO*A060LDC Series
Страница 4: ...1 OUTDOOR UNIT DTW_1SP003E_02 CHAPTER01 2013 2 28 SINGLE PHASE TYPE WO A060LDC WO A080LDC WO A100LDT...
Страница 13: ...OU01 08 Outdoor unit Single phase OUTDOOR UNIT WO A060 100LD OUTDOOR UNIT WO A060 100LD MODELS WO A100L Unit mm...
Страница 17: ...OU01 12 Outdoor unit Single phase OUTDOOR UNIT WO A060 100LD OUTDOOR UNIT WO A060 100LD MODELS WO A080L...
Страница 18: ...OU01 13 Outdoor unit Single phase OUTDOOR UNIT WO A060 100LD OUTDOOR UNIT WO A060 100LD MODELS WO A100L...
Страница 32: ...2 HYDRAULIC UNIT DTW_1SP003E_02 CHAPTER02 2013 03 22 SINGLE PHASE TYPE WS A050DD6 WS A100DD6...
Страница 46: ...3 CONTROL SYSTEM DTW_1SP003E_02 CHAPTER03 2013 03 22 WS A050DD6 Hydraulic unit WS A100DD6 Hydraulic unit...
Страница 125: ...CS01 78 Control system CS01 78 CONTROL SYSTEM CONTROL SYSTEM...