OUTDOOR SENSOR
The outdoor sensor is required for the heat pump to operate correctly.
Consult the fitting instructions on the sensor’s packaging.
Place the sensor on the coldest part, generally the northern or north-eastern side.
In any case, it must not be exposed to the morning sun.
It must be installed so as to be easily accessible but at least 2,5 m from the floor.
It is essential that it avoid any sources of heat such as flues, the upper parts of doors and windows,
proximity to extraction vents, the underneath of balconies and under-eave areas which would isolate the
sensor from variations in the outdoor air temperature.
Connect the outdoor sensor to the M and BX4 (B9) terminals on the heat pump control board.
-
ROOM THERMOSTAT AND / OR REMOTE CONTROL
The room thermostat (remote control) is optional.
Consult the fitting instructions on the sensor’s packaging.
The sensor must be installed in the living room area on a very uncluttered wall, 1,5 m above the floor.
Avoid direct sources of heat (chimney/flue, television, cooking hobs), draughty areas (ventilation, door, etc.).
Air leaks in the seals in the constructions are often translated into cold air blowing through the electrical
conduits. Lag the electrical conduits if there is a cold draught on the back of the IR sensor.
Installing a room thermostat
•
Room thermostat
-
Connect the room thermostat to the X86 connector of the heat pump’s regulator board using the
-
connector provided (terminals 1, 2).
Room thermostat radio
-
Connect the wireless room thermostat radio to the connector X60.
-
Installing a remote control
•
Remote control unit
-
Connect the remote control unit to the X86 connector of the heat pump’s regulator board using the
-
connector provided (terminals 1, 2 and 3).
Remote control unit radio
-
Connect the wireless remote control unit radio to the connector X60.
-
DHW SENSOR
If the installation is equipped with a DHW tank (with electric back-up):
Place the domestic hot water sensor in the housing for the cylinder sensors.
-
Connect the domestic hot water sensor to terminal BX3 and M.
-
Содержание WO*A060LDC Series
Страница 4: ...1 OUTDOOR UNIT DTW_1SP003E_02 CHAPTER01 2013 2 28 SINGLE PHASE TYPE WO A060LDC WO A080LDC WO A100LDT...
Страница 13: ...OU01 08 Outdoor unit Single phase OUTDOOR UNIT WO A060 100LD OUTDOOR UNIT WO A060 100LD MODELS WO A100L Unit mm...
Страница 17: ...OU01 12 Outdoor unit Single phase OUTDOOR UNIT WO A060 100LD OUTDOOR UNIT WO A060 100LD MODELS WO A080L...
Страница 18: ...OU01 13 Outdoor unit Single phase OUTDOOR UNIT WO A060 100LD OUTDOOR UNIT WO A060 100LD MODELS WO A100L...
Страница 32: ...2 HYDRAULIC UNIT DTW_1SP003E_02 CHAPTER02 2013 03 22 SINGLE PHASE TYPE WS A050DD6 WS A100DD6...
Страница 46: ...3 CONTROL SYSTEM DTW_1SP003E_02 CHAPTER03 2013 03 22 WS A050DD6 Hydraulic unit WS A100DD6 Hydraulic unit...
Страница 125: ...CS01 78 Control system CS01 78 CONTROL SYSTEM CONTROL SYSTEM...