RF MODULE (Optional parts)
4-43
MODEL
: UTW-M60XD, UTW-MRCXD
The wireless components should be located such that transmission is as interference-free as possible.
●
The following criteria must be observed:
Not in the vicinity of electrical cables, strong magnetic fields or equipment, such as PCs, TV sets,
●
microwave ovens, etc.
Not near larger metal structures or constructional elements with fine metal meshes, such as special glass
●
or special concrete
The distance to the transmitter should not exceed 30 meters or 2 floors
●
UTW-M60XD
z
Do not install the RF module inside metal casings.
●
UTW-MRCXD
z
Connections
z
UTW-M60XD
-
The prefabricated cable is to be connected to
terminal X60 of the heat pump’s regulator.
UTW-MRCXD
-
The RF module must be connected to the
connector X150 (terminals 1, 2, 3) of the regulation
extension kit. To do this, you can use a 0.5mm²
cable of the two-pair telephone cable type.
If the cable is shielded, the shielding can be
connected to the controller terminal 2. It may under
no circumstances be connected on both sides, i.e.
heat pump regulator side and room unit side.
Содержание WO*A060LDC Series
Страница 4: ...1 OUTDOOR UNIT DTW_1SP003E_02 CHAPTER01 2013 2 28 SINGLE PHASE TYPE WO A060LDC WO A080LDC WO A100LDT...
Страница 13: ...OU01 08 Outdoor unit Single phase OUTDOOR UNIT WO A060 100LD OUTDOOR UNIT WO A060 100LD MODELS WO A100L Unit mm...
Страница 17: ...OU01 12 Outdoor unit Single phase OUTDOOR UNIT WO A060 100LD OUTDOOR UNIT WO A060 100LD MODELS WO A080L...
Страница 18: ...OU01 13 Outdoor unit Single phase OUTDOOR UNIT WO A060 100LD OUTDOOR UNIT WO A060 100LD MODELS WO A100L...
Страница 32: ...2 HYDRAULIC UNIT DTW_1SP003E_02 CHAPTER02 2013 03 22 SINGLE PHASE TYPE WS A050DD6 WS A100DD6...
Страница 46: ...3 CONTROL SYSTEM DTW_1SP003E_02 CHAPTER03 2013 03 22 WS A050DD6 Hydraulic unit WS A100DD6 Hydraulic unit...
Страница 125: ...CS01 78 Control system CS01 78 CONTROL SYSTEM CONTROL SYSTEM...