4. Remove the meter adapter. Be careful not to 

misplace any of the O-rings.

5. Use a needle-nose pliers to grasp one of the four 

vanes of the gland, Figure 18, and pull straight out 
to remove the gland from the adapter.

Figure 18

6. Carefully remove the turbine wheel from the 

housing. Use a toothbrush to lightly scrub the iron 
off the magnet. Iron buildup on the wheel surfaces 
can be removed by soaking the wheel in a mild 
sodium hydrosulfite (e.g., RoVer*) solution for a few 
minutes, then flushing thoroughly with water.

7. Carefully reinstall the turbine wheel into the 

adapter. Make sure that the shaft of the wheel seats 
into the bearing of the adapter and that the dimple 
on the wheel faces you.

8. Carefully reinstall the gland into the adapter. Make 

sure that the shaft of the wheel seats into the 
bearing of the gland. Press the gland all the way in 
and check that the wheel rotates freely.

9. Reinstall the meter adapter, O-rings, piping boss or 

bypass valve. Tighten all fasteners and turn on the 
water supply or put the bypass valve(s) into the 
service position. Purge the air out of the system.

To check for proper meter operation, open a 
downstream faucet and observe the water flow 
indication (flashing colons on time display) on the 
control display.

*RoVer is a trademark of Hach Chemical Company.

Disinfection of Water Conditioners

The construction materials of the water conditioning 
system do not support bacterial growth or contaminate 
the water supply. However, we recommend that the 
conditioner be disinfected after installation and before 
the conditioner is used to treat potable water. In 
addition, a conditioner can become fouled with organic 
matter during normal usage or with bacteria from the 
water supply. Periodic disinfection is recommended for 
all conditioners. Use one of the following methods of 
disinfection based on operating conditions, style of 
conditioner, type of ion exchanger, and disinfectant 
available.

Sodium Hypochlorite 5.25%

Sodium Hypochlorite solutions can be used with 
polystyrene resin, synthetic gel zeolite, greensand, and 
bentonites and are available under trade names such 
as Clorox, Linco, Bo Peep, White Sail, and Eagle Brand 
Bleach. Adjust the dosage if stronger commercial 
solutions are used.

The recommended dosage for 5.25% solutions is:

Polystyrene resin: 1.2 fluid ounces per cubic foot.

Non-resinous exchangers: 0.8 fluid ounce per 
cubic foot.

Complete the following steps to disinfect the 
conditioner:  Add the sodium hypochlorite solution to 
the brine well of the brine tank.  Make sure that the 
brine tank has water in it so the solution is carried into 
the conditioner.  Proceed with normal regeneration.  
Refer to the Manual Regeneration section in this 
manual.

Calcium Hypochlorite

Calcium hypochlorite, 70% available chlorine, is 
available in several forms including tablets and 
granules.  These solid materials can be used directly 
without dissolving before application.

The recommended dosage for calcium hypochlorite is 
two grains (approximately 0.1 ounce) per cubic foot.

Complete the following steps to disinfect the 
conditioner: Add the calcium hypochlorite solution to 
the brine well of the brine tank. Make sure that the brine 
tank has water in it so the solution is carried into the 
conditioner. Proceed with normal regeneration. Refer to 
the Manual Regeneration section in this manual.

Inlet

Outlet

Drain

Содержание Series 255

Страница 1: ...Water Conditioning Control System Dealer Installation Operation and Maintenance Manual Series 255 Valve 960 Control...

Страница 2: ...on Service 14 Removing the Control Preventive Maintenance 15 Injector Screen and Injector Water Meter Disinfection of Water Conditioners 16 Sodium Hypochlorite 5 25 Calcium Hypochlorite Specifications...

Страница 3: ...ons include starting a regeneration only at a specific time of day or having an immediate regeneration when the capacity is exhausted The control can also have a fixed reserve which is a percentage of...

Страница 4: ...Five cycle operation provides for downflow conditioned water upflow backwash downflow brining and slow rinse downflow fast rinse and refill of the brine tank Valve discs are held closed by water press...

Страница 5: ...water heater Water heaters can transmit heat back down the cold water pipe into the control valve Hot water can severely damage the conditioner A 10 foot 3 m total pipe run including bends elbows etc...

Страница 6: ...into the tank and tighten with the plastic thumb nut and gasket as illustrated in Figure 6 3 Attach a length of 1 2 inch 1 3 cm tubing not supplied to the fitting and run to the drain Figure 6 Overflo...

Страница 7: ...the Control The control has default values for most parameters that were set at the factory but there are key items that need to be entered at the time of installation Time of Day Time of Regeneratio...

Страница 8: ...and the control accepts the new setting After approximately 30 seconds the control starts alternating the display between Time of Day and Capacity Note If a beep sounds the new setting is not accepted...

Страница 9: ...s Parameter Range of Values Minimum Increments Default Units of Measure Notes Name Description P1 Time of day AM or PM 1 00 to 12 59 00 00 to 23 59 1 None Hour minute Range depends on value selected f...

Страница 10: ...and the far right number on the display starts flashing If you want to change this number press the up arrow button or the down arrow button To skip the number without changing press the left arrow bu...

Страница 11: ...er for a 12 hour clock or enter 1 for a 24 hour clock P14 Calendar override 0 to 30 1 0 Days 0 no calendar override Skip this parameter for no calendar override or enter a value P15 Reserve type 0 to...

Страница 12: ...e two settings can only be viewed when the control is in the Level II mode The settings will be skipped when the control is in the Level I mode When Parameter 18 is set to zero the Salt Amount and Cap...

Страница 13: ...options for this control fixed reserve and historical water usage pattern They are selected with Parameter P15 Fixed reserve When the fixed reserve is selected the control multiplies the maximum syste...

Страница 14: ...g straight up This occurs when the indicator knob is rotated to the refill position Press down on the back of the camshaft to disengage it from the rear hoop of the top plate Figure 12 Slide the camsh...

Страница 15: ...crew and remove the injector screen and injector cap 5 Clean screen with a fine brush Flush with water until clean 6 Using a needle nose pliers pull the injector straight out 7 Flush water into the in...

Страница 16: ...to treat potable water In addition a conditioner can become fouled with organic matter during normal usage or with bacteria from the water supply Periodic disinfection is recommended for all condition...

Страница 17: ...let outlet 3 8 inch BSPT drain 1 inch BSPT inlet outlet 1 2 inch BSPT drain Optional Bypass Valve 3 4 inch 19 1 mm or 1 inch 25 4 mm copper tailpiece 1 2 inch NPT male drain Valve Module Tank Adapter...

Страница 18: ...18 Pressure Graphs Tested with 3 4 inch Brass Manifold Bar Bar Bar...

Страница 19: ...19 Control Valving Identification Flow Diagrams Brine 1 Inlet 2 Bypass 4 Outlet 3 Rinse Drain 5 Backwash Drain 6 Valve Disc Operation...

Страница 20: ...20...

Страница 21: ......

Страница 22: ...Ring 3 4 x 1 x 1 8 EP 1 6 Drain Control Assembly with O Rings 1 14 1031402 Locking Bar English Language 1 1034162 No 6 for 6 inch Diameter Tank 15 1006093 Screw No 8 x 9 16 inch 1 1000209 No 7 for 7 i...

Страница 23: ...23 Meter Adapter Bypass Valve Piping Boss and Wall Mount Transformer Inlet Outlet Drain...

Страница 24: ...1 1040280 1 inch NPT Noryl 1001613 3 4 inch CPVC Tube Adapter Kit 1 1040283 3 4 inch BSPT Noryl 1001614 1 inch CPVC Tube Adapter Kit 1 1040284 1 inch BSPT Noryl 1001615 25 mm CPVC Tube Adapter Kit 1 2...

Страница 25: ...ve bypass into the bypass position and open the backwash drain valve the sixth valve back from the control with a screwdriver see Figure 11 Restore system water pressure when the service work is compl...

Страница 26: ...e meter probe e Defective circuit board a Shift bypass valve into service position b Fully insert probe into meter housing c Remove meter housing free up turbine and flush with clean water Turbine sho...

Страница 27: ...ased f Restricted meter turbine rotation due to foreign material in meter housing g Excessive water usage below 1 5 gallon per minute a Repeat regeneration making certain that correct salt dosage is u...

Страница 28: ...Replace both injector and injector cap 18 No conditioned water after regeneration a Unit did not regenerate b No salt in brine tank c Plugged injector d Air check valve closed prematurely a Check for...

Отзывы: