9.3
External cooling water system
Fig 9-5
External cooling water system 1 x Wärtsilä L46F (DAAE022048B)
System components
Transfer pump
4P09
Heater (pre-heating unit)
4E05
Circulation pump
4P06
Central cooler
4E08
Air venting
4S01
Cooler (installation equipment)
4E12
Additive dosing tank
4T03
Cooler (generator)
4E15
Drain tank
4T04
Pre-heating unit
4N01
Expansion tank
4T05
Evaporator unit
4N02
Temperature control valve (heat recovery)
4V02
Stand-by pump (HT)
4P03
Temperature control valve (central cooler)
4V08
Circulation pump (preheater)
4P04
Stand-by pump (LT)
4P05
Pipe connections
HT-water air vent from exhaust valve seat
424
HT-water inlet
401
LT-water inlet
451
HT-water outlet
402
LT-water outlet
452
HT-water from stand-by pump
408
LT-water air vent from air cooler
454
HT-water drain
411
LT-water from stand-by pump
457
HT-water air vent from air cooler
416
Wärtsilä 46F Product Guide - a19 - 1 December 2017
9-7
9. Cooling Water System
Wärtsilä 46F Product Guide
Содержание 12V46F
Страница 1: ...PRODUCT GUIDE Wärtsilä 46F ...
Страница 44: ...This page intentionally left blank ...
Страница 52: ...This page intentionally left blank ...
Страница 78: ...This page intentionally left blank ...
Страница 102: ...This page intentionally left blank ...
Страница 124: ...This page intentionally left blank ...
Страница 144: ...This page intentionally left blank ...
Страница 162: ...This page intentionally left blank ...
Страница 186: ...This page intentionally left blank ...
Страница 192: ...This page intentionally left blank ...
Страница 194: ...This page intentionally left blank ...
Страница 197: ......
Страница 198: ......
Страница 199: ......