6.3.3.7
Sludge tank (1T05)
The sludge tank should be located directly beneath the separators, or as close as possible
below the separators, unless it is integrated in the separator unit. The sludge pipe must be
continuously falling.
6.3.4
Fuel feed system - MDF installations
Fig 6-5
Example of fuel oil system, MDF, single engine installation (DAAE022042b)
* To be remotely operated if located < 5 m from engine.
Pipe connections
System components
Fuel inlet
101
Cooler (MDF)
1E04
Fuel outlet
102
Automatic filter (MDF)
1F04
Leak fuel drain, clean fuel
103
Fine filter (MDF)
1F05
Leak fuel drain, dirty fuel
104
Suction strainer (MDF)
1F07
Flow meter (MDF)
1I03
Fuel feed pump unit (MDF)
1N08
Wärtsilä 46F Product Guide - a19 - 1 December 2017
6-13
6. Fuel Oil System
Wärtsilä 46F Product Guide