Fig 9-7
External cooling water system 2 x Wärtsilä L46F (DAAE022047b)
System components
Transfer pump
4P09
Heater (preheater)
4E05
Air venting
4S01
Central cooler
4E08
Additive dosing tank
4T03
Cooler (reduction gear)
4E10
Drain tank
4T04
Cooler (installation equipment)
4E12
Expansion tank
4T05
Pre-heating unit
4N01
Temperature control valve (heat recovery)
4V02
Evaporator unit
4N02
Temperature control valve (central cooler)
4V08
Circulation pump (preheater)
4P04
Circulation pump
4P06
Pipe connections
HT-water air vent from exhaust valve seat
424
HT-water inlet
401
LT-water inlet
451
HT-water outlet
402
LT-water outlet
452
HT-water from preheater to HT-circuit
406
LT-water air vent from air cooler
454
HT-water drain
411
HT-water air vent from air cooler
416
Wärtsilä 46F Product Guide - a19 - 1 December 2017
9-9
9. Cooling Water System
Wärtsilä 46F Product Guide
Содержание 12V46F
Страница 1: ...PRODUCT GUIDE Wärtsilä 46F ...
Страница 44: ...This page intentionally left blank ...
Страница 52: ...This page intentionally left blank ...
Страница 78: ...This page intentionally left blank ...
Страница 102: ...This page intentionally left blank ...
Страница 124: ...This page intentionally left blank ...
Страница 144: ...This page intentionally left blank ...
Страница 162: ...This page intentionally left blank ...
Страница 186: ...This page intentionally left blank ...
Страница 192: ...This page intentionally left blank ...
Страница 194: ...This page intentionally left blank ...
Страница 197: ......
Страница 198: ......
Страница 199: ......