6.11.2 CONTROL ACCESSORIES FOR CASCADE SYSTEM (CONTINUATION)
Accessories Code Accessories Name
Description
Adaptable
Product
Product View
153.11.660.600001
WDHS-01-Exterior
Temperature Sensor
Sensor that allows the boiler to regulate according to exterior
temperature.
Viwa 50-150
153.11.660.600045
RC 21.11-Room Thermostat
with Timer
Unit that can be used as a thermostat OR timer to provide
weekly/daily program to heater and boiler circuit
Viwa 50-150
153.11.660.600049
QAZ36-Hot Water Tank
/ Hydraulic Separator
Sensor - Immersion Type
The immersion type sensor that will be used to measure the
Hot Water Tank or Hydraulic Separator temperature and report
to boiler
Viwa 90-150
153.11.660.600050
QAD36-System Stream
Sensor- Surface Type
A clamp-type sensor that provides temperature measurement
over the pipe at the outlet of the Hydraulic Separator. It is used
to measure the stream water temperature of low temperature
zone in double-zone systems.
Viwa 90-150
153.11.660.600053
MST80 Adjustable Surface
Thermostat
A clamp-type adjustable thermostat for heating zone.
Viwa 50-150
153.11.660.600047
MLC 30-Multi Zone
Module
Unit controlling the Low Temperature/Underfloor Heating Zone
(mixed valve circuit) of Viwa 90, Viwa 115, Viwa 125 and Viwa
150 boilers.
Viwa 50-150
151.11.05.006
RVS-AVS Cascade Panel
Set
This set is for the cascade and zone management system which
involves RVS 43 boiler control device, AVS 37 display module
and RVS-AVS connection cable.
Viwa 50-150
153.11.660.600051
RVS 43.345 / 101
Boiler Controller
Control unit for Viwa 90 - 150 Boilers that can cascade over
OpenTerm for up to 8 boilers (up to 15-cascade)
With RVS 43, 1 Radiator Circuit, 1 Underfloor Heating Circuit and
1 Hot Water Tank can be managed.
Viwa 90-150
153.11.660.600056
OCI 365.03 / 101
Opentherm Module
Communication unit for each boiler if RVS unit is used for Viwa
90 - 150 Boilers
Viwa 90-150
153.11.660.600057
AVS 37.294 / 509 RVS
Display Module
1 must be purchased if RVS unit is used for Viwa 90 - 150 Boilers
RVS unit control display
Viwa 90-150
153.11.660.600076
AVS 82.490 / 109
RVS-AVS Connection
Cable [40 cm]
1 must be purchased if RVS unit is used for Viwa 90 - 150 Boilers
The cable that provides the connection between the RVS unit
and the control display or RVS unit and AVS75 unit or AVS75
unit and AVS75 unit (with each other)
Viwa 90-150
153.11.660.600058
AVS 82.491 / 109
RVS - AVS Connection
Cable [100 cm]
1 must be purchased if RVS unit is used for Viwa 90 - 150 Boilers
The cable that provides the connection between the RVS unit
and the control display or RVS unit and AVS75 unit or AVS75
unit and AVS75 unit (with each other)
Viwa 90-150
153.11.660.600071
QAC34/101 Exterior
Temperature Sensor
1 must be purchased if RVS unit is used for Viwa 90 - 150 Boilers.
The sensor that must be connected to the RVS unit.
Viwa 90-150
153.11.660.600072
QAA55.110/101 Room Unit
(Basic)
Small screen room thermostat with Economy and Comfort
mode selection and adjusting temperature
Viwa 90-150
153.11.660.600073
QAA74.611/101 Room Unit
(Advanced)
Wide and Illuminated screen room thermostat with Economy
and Comfort mode selection and adjusting temperature
Viwa 90-150
153.11.660.600074
AVVS75.390/101
(Additional Module)
ZONE EXPANSION MODULE (Module for additional zone with 3
relay outputs)
Viwa 90-150
153.11.660.600077
OZW672.01-Web Server 1
LPB Device
The OZW672.01 web server connected to the RVS 43 Boiler
Controller allows remote monitoring and monitoring of the
heating center via web and smartphone application.
Viwa 90-150