CHAPTER-3
BOILER AND PARAMETER SETTINGS
3.1. CONTROL PANEL
3.2. SCREEN SYMBOLS
Designation:
Viwa 90 - 115 - 125 - 150
POS NO
Symbol
Description
Use
0
Op. Mode Summer
Symbol lit (if boiler is in Summer mode) during Stand-by, Antifreeze, DHW.
1
Op. Mode Winter
Symbol lit (if boiler is in Winter mode) during Stand-by, Anti-freeze, Heating, DHW.
2
DHW operation
Symbol lit during DHW operation and during DHW set temperature setting procedure.
3
Heating Operation
Symbol lit during heating operation (symbols 1 and 2 lit individually or together based on whether
the request arises from zone 1, zone 2 or both, radiator symbol always present, either fixed or
flashing in the presence of heat request from zone 3) and during the setting procedure for the
heating set temperature value (symbols 1 and 2 lit individually based on whether you are setting
the set Temperature for zone 1 or zone 2, radiator symbol without other symbols indicates set
temperature for zone 3).
4
Power Bar
Indication of the instant power level of the boiler.
Lit during any type of burner operation:
- First segment only if power is between 0% and 25%
- First two segments if power is between 25% and 50%
- First three segments if power is between 50% and 75%
- All segments if power is between 75% and 100%
5
Flame present
Symbol lit during burner operation if the flame control device is detecting a flame (even in the
presence of remote control). Symbol flashing when flame detection circuit is in error mode
(parasite flame) in addition to fixed lighting of associated alarm code.
6
lockout caused by No
Flame
Flashing1 symbol if the boiler is in Lockout error mode due to no flame in addition to (fixed)
lighting of associated alarm code.
7
Setting Values
Symbol lit when it is possible to set Heating Set Temperature values;
( Z1, Z2, Z3) and DHW Set Temperature values.
Symbol lit when it is possible to set installer parameter values and OEM values.
8
Alarm
Symbol lit when the boiler is in error mode together with associated alarm code and any other
specific symbols.
9
Sign
Signs + and – to be used each time you need to view or set a value by increasing or decreasing
(e.g. values associated with an offset) or a negative value.