Fault finding for Overheat and No display problems
Warmhaus
Viwa 90-115-125-150
Rev. No:
0
Drw. No:
WH.17.733
Is the Boiler and CH System filled with water, water pressure in between
1,5 - 2,0 bar and all isolation and radiator valves open?
Is there 230Vac to the boiler at L and N?
Replace the PCB
Is the wiring from the terminal block to the Main PCB
connected securely?
ON TERMINAL BLOCK FUSE : 6 A FUSE, Check FUSE is OK?
ON PCB FUSE : 3 A FUSE, Check PCB FUSE is OK?
Is the Flow/Return Differential across the boiler in excess of 30°C?
( normally should not exceed 20-22° C )
Check the Flow and Return NTC
Check resistance using a suitable multimeter connected across the
thermistor’s terminal pins
At 25°C expect 10000 Ohms ( 10.300 - 9.700 )
At 60°C expect 2488 Ohms ( 2562 - 2413 )
At 80°C expect 1258 Ohms ( 1295 - 1220 )
Is problem solved?
OK, now restart
Full fill the system and boiler with water and vent the system and
open all isolation valves, then restart boiler
Supply power to the boiler & Restart
Connect the wiring from the terminal block to the Main PCB
securely. Change the fuse on the terminal.
Supply power to the boiler & Restart
Change the fuse on the PCB.
Supply power to the boiler & Restart
Check that the Pump is working and rotating freely.
Is the Differential now below 20°C?
Check the pump electrical
connector and PWM
connector, Is
Pump working ?
Replace the Pump,
then restart boiler, Is
problem solved?
OK, now restart
boiler.
Check the heat
exchanger is
blocked ? if
blocked replace the
heat exchanger, and
restart boiler.
OK, now restart
boiler.
OK, now restart boiler.
Is the problem solved?
Check the 3 Way Valve
DHW loop during CH
operation. If 3 Way valve
leaky OR BLOCKED
replace it. Is problem
solved?
NO
NO
NO
NO
YES
NO
YES
YES
YES
YES
YES
YES
NO
HAYIR
NO
YES
NO
YES
YES
NO
YES
OVERHEAT
4.2. NO DISPLAY
4.1. OVERHEAT /NO DISPLAY