![W&T 58031 Скачать руководство пользователя страница 93](http://html1.mh-extra.com/html/wandt/58031/58031_manual_865891093.webp)
93
W&T
Configuration of the serial port
Subject to error and alteration
n
Pin: RTS & Pin: DTR
The following functions can be assigned to the outputs
RTS and DTR:
1. Flow Control
– If this function is turned on, the
Com-Server handles the RS232 flow control through the
corresponding output. The ready state for serial data is
signaled by a HIGH signal (+3...12V). If the memory limit
of the input buffer is reached, the line is set to LOW (-
3...-12V).
2. Show Connection
– The output is switched to the
serial port depending on an existing TCP connection.
HIGH (+3...12V) indicates an existing connection.
3. NO (Default=HIGH)
– The outputs are not used by
the Com-Server and carry a constant HIGH level
(+3...12V). A network application can use the control
port of the Com-Server (see „Enhanced services of the
Com-Server“) to temporarily influence the level.
4. NO (Default=LOW)
– The outputs are not used by
the Com-Server and carry a constant LOW level (-3...-
12V). A network application can use the control port of
the Com-Server (see „Enhanced services of the Com-Ser-
ver“) to temporarily influence the level.
n
PIN: CTS und PIN: DSR
The inputs CTS and DSR can be assigned the following
functions:
1. Flow Control
– The serial flow control is performed
using the corresponding pin. Serial data are output only
if the input was set to HIGH (+3...12V) by the connected
terminal device.
2. OPEN/CLOSE
– Connection This option for TCP
connection building and ending can be used to control
connection building and ending in all Com-Server client
operating modes. If the IP address and the TCP port are
stored in the Com-Server, a HIGH level (+3...12V) on the
corresponding input establishes a connection. The
connection is closed with a LOW level (-3...-12V).
Содержание 58031
Страница 8: ...W T ...
Страница 38: ...38 W T Form factors ...
Страница 102: ...102 W T The protocol stack of the Com Server ...
Страница 128: ...128 W T The Windows COM redirector ...
Страница 134: ...134 W T Box to Box mode ...
Страница 152: ...152 W T Data transfer per Telnet ...
Страница 192: ...192 W T Firmware update of the Com Server ...
Страница 215: ...215 W T Appendix Subject to error and alteration Declaration of conformity ...