83
W&T
The base configuration of the Com-Server
Subject to error and alteration
Example:
A TCP client has opened a connection to TCP
server port 8000 of the Com-Server and the network
connection is interrupted. After the set keep-alive time plus
2s for two repetitions has elapsed, the Com-Server closes
the connection and is again ready for any other clients.
n
Retransmission Timeouts (ms)
(Default: 240)
This timeout determines what time must elapse before
network packets are repeated if necessary. In most
networks the default setting of 240ms can be used. Only
when there are very long latency times between the Com-
Server and its respective communications partner would
you need to increase this value.
7.3.2 Menu: SETUP System
r
Telnet Password
Here you may specify an 8-character hexadecimal password
(valid charcters = 0...9 and a...f) for protecting the
configuration menu from unauthorized access. The factory-
set password is 00000000. With the password you have
unrestricted access to the Com-Server‘s configuration menu.
You are prompted for a valid password as soon as the Telnet
connection for the configuration port is opened. An incorrect
entry denies access to the Com-Server‘s configuration port.
1
Resetting or changing any parameters including the
password is only possible if you know the old
password. Make sure you write it down and keep it in a safe
location.
Содержание 58031
Страница 8: ...W T ...
Страница 38: ...38 W T Form factors ...
Страница 102: ...102 W T The protocol stack of the Com Server ...
Страница 128: ...128 W T The Windows COM redirector ...
Страница 134: ...134 W T Box to Box mode ...
Страница 152: ...152 W T Data transfer per Telnet ...
Страница 192: ...192 W T Firmware update of the Com Server ...
Страница 215: ...215 W T Appendix Subject to error and alteration Declaration of conformity ...