13.1.1 Configuring Box-to-Box mode
1
Only the Master port is configured for „Box to Box“
mode; The
Slave IP address
and
Slave port number
are
set only on the Master port! Settings in the Special Options
submenu and parameterizing of the serial port can and must
be done on both ports (see examples at the end of this section).
The following settings must be made in the Submenu
SETUP
Port x
r
TCP/IP Mode
r
Box to Box
of the Com-Server which is
specified as the master:
n
Slave Port
(set only for master port)
Port of the serial Com-Server Slave port. The following port
numbers are pre-configured at the factory:
•
Port A = 8000 (all models with only one serial port)
•
Port B = 8100
•
Port C = 8200
•
Port D = 8300
The serial port of a Com-Server can easily be „connected“
with one of the up to four serial ports of another Com-Ser-
ver.
n
Slave IP-Address
(set only for master port)
IP address of the Com-Server in which the Slave port is
located.
Once you have entered all the parameters in the Com-Server
port menu, press the ENTER key several times to return to the
main menu and save the entries with
SAVE Setup
. The message
Saving...
appears, then „Box to Box“ mode is activated. The entry
Box to Box Master
now appears in the S
ETUP Port x
r
Port State
r
Connection State
menu. The connection status can be read
at any time in this menu both for the Master and for the Slave
port.
Содержание 58031
Страница 8: ...W T ...
Страница 38: ...38 W T Form factors ...
Страница 102: ...102 W T The protocol stack of the Com Server ...
Страница 128: ...128 W T The Windows COM redirector ...
Страница 134: ...134 W T Box to Box mode ...
Страница 152: ...152 W T Data transfer per Telnet ...
Страница 192: ...192 W T Firmware update of the Com Server ...
Страница 215: ...215 W T Appendix Subject to error and alteration Declaration of conformity ...