Assigning the IP address
This function can later be reactivated through the Telnet
configuration under
SETUP System
r
SETP TCP/IP
r
BOOTP
Client
.
1
To prevent unintended address assignments or changes,
we recommend deactivating the DHCP, BOOTP and RARP
protocols if they are not expressly used in the respective
network environment. Com-Servers with incorrectly assigned IP
addresses can be easily found after the fact using the scan
function of the WuTility management tool and reconfigured.
2.3.3 Serial activation of Web Based Management
To further configure the Com-Server you can use either Telnet
protocol or an Internet browser, although only Telnet is an
option in the Com-Server as shipped from the factory. You can
activate Web Based Management as part of the serial IP
assignment. To do this, enter
+w[Portno.]
directly after the IP
address or address string. Here
Portno.
is the desired TCP port
in decimal format.
Example 1
: Deactivating DHCP/BOOTP/RARP and activating Web
Based Management on TCP port 8080.
xxx
->
Com-Server
IP no.+<ENTER>:
<- Com-Server
172.17.231.99,255.255.0.0,172.17.231.52-0+w8080
-> Com-Server
172.17.231.99 ,255.255.0.0,172.17.231.52-0+w8080
<- Com-Server
Example 2
: Activation of Web Based Management on TCP port
80. The status of DHCP/BOOTP/RARP remains unchanged.
xxx
->
Com-Server
IP no.+<ENTER>:
<-
Com-Server
172.17.231.99+w80
->
Com-Server
172.17.231.99-1
<-
Com-Server
Содержание 58031
Страница 8: ...W T ...
Страница 38: ...38 W T Form factors ...
Страница 102: ...102 W T The protocol stack of the Com Server ...
Страница 128: ...128 W T The Windows COM redirector ...
Страница 134: ...134 W T Box to Box mode ...
Страница 152: ...152 W T Data transfer per Telnet ...
Страница 192: ...192 W T Firmware update of the Com Server ...
Страница 215: ...215 W T Appendix Subject to error and alteration Declaration of conformity ...