![WAM WAMFLO FOOD FN200X Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/wam/wamflo-food-fn200x/wamflo-food-fn200x_assembly-and-main-instructions-for-use-and-maintenance_3653302046.webp)
5.0 INSTALLATION AND FIXING
WAMFLO
®
FN200X
2
FIL.WAMFLO_FN200.EX.M.A7.0522.EN Issue: A7
05.22
42
Anti-explosion panel flange
5.4 Installing the anti-explosion panel
The filters
WAMFLO
®
ATEX
can be pre-arranged for the installation of anti-explosion panel. The prearrange-
ment consists of a membrane holder (A) bolted to the filter (C). The membrane (B) can be provided by
WAM
®
or purchased by the customer elsewhere. Both the membrane holder and the membrane are supplied in sepa-
rate packagings.
The membrane holder MUST be bolted to the filter and is provided with a perimeter seal to be inserted between
the filter and the holder. To fit the holder to the filter follow the modalities previously described for the connec
-
tion between the filter and the filter flange. Once the holder has been bolted to the filter, the holder unit
MUST be fitted to the filter flange according to the procedures previously described.
ANTI-EXPLOSION PANEL
Prior to installation, read the safety instructions.
Danger - Warning
The membrane MUST be installed after the filter has been positioned and assembled.
ANTI-EXPLOSION PANEL
To fit a new explosion vent panel or replace an existing one, proceed as described below (only for panel sup
-
plied by WAM; otherwise consult the instructions given by the panel manufacturer):
1.
Carry out a dimensional check of the existing flanges/frames between which the panel will be secured;
check also the quality of the locking surfaces.
2.
Unpack then the panel and ensure it is in perfect condition. Wipe the locking surfaces with a cloth.