5.0 INSTALLATION AND FIXING
WAMFLO
®
FN200X
2
FIL.WAMFLO_FN200.EX.M.A7.0522.EN Issue: A7
05.22
41
5.3 Emissions sampling kit
1) Make sure the air jet cleaning system of the filter is
not in running and open the cover.
2) Fix the blind flanges in the rear slits and the two
flanges with the tube in the front part of the filter.
See fig. 1
3) Fix the support A to the seal frame as indicated in
Fig. 2 and remove the 2 screws of the plate.
4) Fix temporarily the flange B to the support A as in
-
dicated in Fig.3.
Fig. 2
Fig. 1
Fig. 3
A
A
B
VERSION FOR STAINLESS STEEL COVER
5) Connect the hose pipes to the related connections
and fix by means of the clamps (see Fig.4).
6) Fit back he cover.
Fig. 4
NOTE:
After having sampled the emissions,
WAM
®
recommends removing the slits occlusion flanges to allow
the filter operating in normal conditions.