WAMFLO
®
FN200X
3.0
3.0 TECHNICAL INFORMATION
2
FIL.WAMFLO_FN200.EX.M.A7.0522.EN Issue: A7
05.22
29
3.24 Options - Anti-explosion panel
The
WAMFLO
®
ATEX
filters can be pre-arranged for the installation of anti-explosion panel. The prearrange
-
ment is available for diameters 600, 800 and 1000 and consists of a membrane holder (A) bolted to the filter.
The membrane (B) can be provided by
WAM
®
or purchased by the customer elsewhere. Both the membrane
holder and the membrane are supplied in separate packagings.
Use the modular key code to select from the following options:
+ = without membrane;
1 = prearrangement for Anti-explosion panel;
2 = with Anti-explosion panel;
Minimum requirements for the membrane:
Vent area: ≥ 0.21 m2;
Pstat ( explosion-proof resistance): 0,1 barg.
Connecting flange of the anti-explosion panel