Chapter 3 Basic Mounting Requirements
NOTE:
Mount tube must be installed at least 1-5/8” below
vehicle chassis to allow room for mounting brackets.
GR00496
INSTALLATION DIMENSIONS
NOTE:
B height dimensions are the maximums for the unloaded vehicle.
BZ-33/44 Short arm, 29-1/2" Optional
A-Dimension
Bed Height
Maximum sill depth Mount tube clearance
15.5
43
4
33.00
18
45
5
31.5
20
47
5.5
30
21.75
49
6.5
28.5
23.75
51
7
26.25
25.5
52.5
7.75
24.5
BZ-33/44 Long arm, 34-1/4" Standard
A-Dimension
Bed Height
Maximum sill depth Mount tube clearance
18.25
49
5
36.75
20.25
51
5.5
35.5
22.25
53
6.5
34.25
24.25
55
7
32.5
26.25
57
7.5
30.75
28
59
8.25
28.5
29.5
60
9
26.75
Note!
Always use the smallest A- dimension possible to maximize ground clearance.