WAGO-I/O-SYSTEM 750
Appendix 389
750-8207 PFC200 CS 2ETH RS 3G
Manual
Draft version 1.2.1 from 2017-09-13, valid from FW Version 02.06.20(09)
Table 307: Description of Configuration Scripts for “Ports and Services” – “PLC Runtime Services”
Parameters Status Call
Output/Input
Effecti
ve
CODESYS 2 Settings
CODESYS2
Webserver
State
read
get_runtime_config cfg-
version=2 Webserver-
state
Read status of the runtime-
specific Webserver
Possible return values:
- enabled
- disabled
Immedia
tely
write
config_runtime cfg-
version=2 Webserver-
state=<value>
Enable/disable runtime-specific
Webserver
Possible entries for <value>:
- enabled
- disabled
CODESYS2
Port
Authentication
read
get_runtime_config cfg-
version=2 authentication
Read status of the port
authentication for communication
between the CODESYS 2 PC
software and the controller
Possible return values:
- enabled
- disabled
Immedia
tely
write
config_runtime cfg-
version=2
authentication=<value>
Possible entries for <value>:
- enabled
- disabled
CODESYS2
Service State
read
get_runtime_config
service-state
Read status of the port for
communication between the
CODESYS 2 PC software and
the controller
Possible return values:
- enabled
- disabled
Immedia
tely
write
config_runtime service-
state=<value>
Possible entries for <value>:
- enabled
- disabled
CODESYS2
Communication
Port
read
get_runtime_config
comm-port
Read value of set network port
for communication between PC
and controller
Default value is 2455
Immedia
tely
write
config_runtime comm-
port=<value>
Change port number
Enter the TCP/IP port number for
<value>.