WAGO I/O SYSTEM 750 XTR
Appendix 157
750-333/040-000 FC PROFIBUS G2 12MBd XTR
Manual
Version 1.4.0
Table 102: Analog Input Modules
– Process Image Information
PBDP module type
PI
Offset
[Byte]
Bit/byte allocation
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
4AI(_PAR)
I
0
Input data
Channel 0, HB
4
(LB
5
)
1
Input data
Channel 0, LB
4
(HB
5
)
2
Input data
Channel 1, HB
4
(LB
5
)
3
Input data
Channel 1, LB
4
(HB
5
)
4
Input data
Channel 2, HB
4
(LB
5
)
5
Input data
Channel 2, LB
4
(HB
5
)
6
Input data
Channel 3, HB
4
(LB
5
)
7
Input data
Channel 3, LB
4
(HB
5
)