WAGO I/O SYSTEM 750 XTR
Appendix 223
750-333/040-000 FC PROFIBUS G2 12MBd XTR
Manual
Version 1.4.0
12.3.2.17 Parameters of the RTC Module
The table shows the parameterization properties of the RTC module.
Table 179: Parameters of the RTC module (RTC)
RTC
Representative of the RTC:
75x-640
Parameterization data length in bytes
Standard parameterization
Structured parameterization
4
8
Parameter
Settings
Description
Scope
Terminal is physically
The I/O module process data is
Module
(optionally) not plugged
•
(optionally) set to zero or filtered by the
fieldbus coupler.
plugged
*)
•
processed by the I/O module.
*)
Default settings
12.3.2.18 Parameters of the Stepper Modules
The table shows the parameterization properties of the stepper modules with
asynchronous diagnostic properties and individual parameters.
Table 180: Parameter of the stepper modules (STEPPER)
STEPPER
Representative of the STEPPER:
75x-670, 75x-671, 750-672, 750-673
Parameterization data length in bytes
Standard parameterization
Structured parameterization
4
8
Parameter
Settings
Description
Scope
Diagnosis
The diagnostic information of the corresponding
channel is
Module
disabled
*)
•
not transmitted to the PROFIBUS P master.
enabled
•
transmitted to the PROFIBUS DP master.
*)
Default settings