24
150 cm
3
- 300 cm
3
OPERATING MANUAL
VERSION 05/2015
ORDER NUMBER DOC2340282
Description
Measuring
Unit
Pump ratio
-
72 :1
Volume fl ow per double stroke (
)
cm3; cc
300
Maximum operating overpressure
MPa; bar; psi
53; 530; 7687
Maximum possible strokes in operation
/min.
40
Maximum recommended strokes per minute in
continuous operation
/min.
30
Minimum/maximum air inlet pressure
MPa; bar; psi
0.25-0.74; 2.5-7.4; 36-107
Compressed air quality: free from oil and water
Quality standard 7.5.4 according to ISO 8573.1, 2010
7: Particle concentration 5 – 10 mg/m3
5: Humidity: Pressure dew
point ≤ +7 °C
4: Oil content ≤ 5 mg/m3
Air inlet (inside thread)
inch
G 1"
Minimum Ø of the compressed air supply line
mm; inch
25; 1.0
Air consumption at 0.6 MPa; 6 bar; 87 psi per double stroke
nl; scf
170; 6
Air motor piston diameter
mm; inch
300; 11.8
Air motor piston stroke
mm; inch
150; 5.9
Sound pressure level at maximum permissible air pressure*
82
Sound pressure level at 0.6 MPa; 6 bar; 87 psi air pressure*
80
Sound pressure level at 0.4 MPa; 4 bar; 58 psi air pressure*
75
Product inlet connection (inside thread)
mm
G1 1/2"
Product outlet (outside thread)
mm
M24x1.5
Weight
kg; lb
80; 176
Product pH value
pH
3.5–9
Maximum product pressure at pump inlet
MPa; bar; psi
2; 20; 290
Material temperature
+5…+80; 41…176
Ambient temperature
Construction and assembly
+5…+50; 41…122
Suspension
-20…+60 ; -4…+140
Relative humidity
%
10–95 (without condensation)
Allowable inclination for operation
± 10
* A rated sound pressure level measured at 1 m distance, L pA1m, according to DIN EN 14462: 2005.
Reference measurements have been made by SUVA (Swiss Accident Insurance Institute).
5.5.3.3
TECHNICAL DATA FOR TIGER
Outgoing air containing oil!
Risk of poisoning if inhaled.
Air motor switching problems.
Provide water-free and oil-free compressed air
WARNING
Содержание Jaguar
Страница 2: ......
Страница 51: ...51 150 cm3 300 cm3 x B_04269 2 A 23 22 24 1 8 15 9 17 OPERATING MANUAL VERSION 05 2015 ORDER NUMBER DOC2340282 ...