85
OPERATING MANUAL
EDITION 02/2016
ORDER NUMBER DOC 2366600
7.4
DEVICE CONFIGURATION
7.4.1
OVERVIEW OF PARAMETERS
Parameter
Value
Description
C12
External set value
specifi cation
off
(factory setting)
The target values for high voltage in kV
and current limitation in μA are adjusted at
the front control panel of the control unit.
on
- The set values for high voltage in kV and
current limitation in μA are predefi ned
using the interface's two analog power
inputs. Application example: Set
value specifi cation by a superordinate
controller (PLC).
- Set values can no longer be adjusted
at the front control panel. All recipe
functions (save, call up recipe, etc.) are
locked.
C13 Lock
off
Lock is deactivated.
(factory setting)
on
Operating inhibit is activated.
- You can select recipes and control
functions.
- The set values (kV and μA) cannot be
adjusted.
pro
Lock pro (program).
- You can select recipes and control
functions.
- The target values (kV and μA) can be
adjusted but cannot be saved in the
recipes.
C19 Reset recipes
no
No reaction
(factory setting)
res
All programs are set to delivery condition,
if "res" is saved with the "Service" button.
C20
Reset
confi guration
no
No reaction
(factory setting)
res
All confi guration parameters are set to
delivery condition (factory setting), if "res"
is saved with the "Service" button.