36
B_05880
A
B
C
2
3
1
2
4
OPERATING MANUAL
EDITION 02/2016
ORDER NUMBER DOC 2366600
5.6.2
PRODUCT PRESSURE GENERATOR
AquaCoat compressed air connection for Puma
The AquaCoat control unit controls the pressure air
("Pomp pressure" regulator, see Chapter 5.6.1.1).
1 Ball valve
2 Compressed air inlet
3 Safety valve
4 Compressed air input for the air motor reversing
valve (mains pressure)
Positions of the ball valve
A
Open: Working position.
B
Closed: The air motor may still be under
pressure.
C
Vent: Pull the ring on the safety valve to vent.
Operating pressure in the air motor is vented
(control air pressure is still present).
The pump is equipped with a special AquaCoat compressed air connection (see below).
All other relevant information can be found in the IceBreaker-operating manual (Order No. see Chapter 1.3.1).
5.6.2.1
PUMA 28-40 PE+TG PNEUMATIC PISTON PUMP