Faults are indicated by the "Fault" LED (24). In addition the error number is shown in the
display (27). If a fault occurs, the high voltage is switched off immediately. The user can
only continue to work once the fault has been remedied and acknowledged with push
button "Service" (25).
Code
display
Malfunction
Cause
Remedy
E11
Ground monitoring
- Grounding cable is interrupted
- Check/replace gun cable
- Gun is not connected
- Check/replace gun
- Connect gun
E12
No coil current/
cascade interrupt
- The cascade is not connected
- Connect the cascade
- Cascade is interrupted
- Check or replace cascade
defective
E13
Coil current too big
- The cascade is defective
- Check or replace cascade
E21-E25 Exception error
- Hardware defect has occurred
- If problem persists, contact the
WAGNER Service Team
E30
Door switch
- Door open
- Close door
- Door switch defective
- Check/replace door switch
E40-E43 Gun communication
faulty
- Gun cable defective
- Check/replace gun cable
- Operating unit of spray gun
defective
- WAGNER Service
- Control unit defective
- WAGNER Service
E60
Password error
- Password not set
- Password to be set by Service
Center