51
B_05896
R
max.
< 1 M
Ω
OPERATING MANUAL
EDITION 02/2016
ORDER NUMBER DOC 2366600
Grounding scheme (example)
Conveyor
Spraying stand
Floor, static dissipative
Signal ground
Signal ground
Minimum cable cross-section
AquaCoat cabinet
4 mm²; AWG 12
Conveyor
16 mm²; AWG 6
Spray booth
16 mm²; AWG 6
Spraying stand
16 mm²; AWG 6
Safe operation of the AquaCoat system is only guaranteed with a grounding connection.
Connect all ground cables using a short and direct route.
Tank
All paints, fl ushing agents and waste tanks have to be made of metal.
All tanks in the cabinet must be connected to the potential equalization.
All further tanks must be grounded.
Work piece