VM 5020W CONTROL UNIT
The assembled spray system can be operated and regulated with the VM 5020W control unit.
5.6
CONTROLS
5.6.1.1
OPERATING ELEMENTS, FRONT SIDE
1
Selector (mains supply)
0 = Control unit switched off .
1 = Control unit switched on.
2
Universal control dial
- Dynamic digital control dial with 32 positions per revolution.
- Adjustment speed is proportional to rotational speed.
- Used to adjust high voltage and spray current.
- For setting parameter values in confi guration mode.
3
Push button "Standby"
For switching to standby mode.
4
Illuminated display "Standby"
Lights up when the device is in standby mode.
5
Push button "Spray current"
For activating the function.
The current limitation is set with the rotary controller (2) and is indicated in the LED
display (27).
- Adjusting range: 10–100 μA.
- Resolution: 1 μA.