background image

3A0156A

Operation

Electric Airless Sprayers

- For Portable Airless Spraying of Architectural Coatings and Paints -

3300 psi (227 bar, 22.7 MPa) Maximum Working Pressure

IMPORTANT SAFETY INSTRUCTIONS
Read all warnings and instructions in this 
manual. Save these instructions.

Related Manuals:
Repair

3A0157

Parts

3A0158

Gun

311861

695/795 Premium Hi

695/795

MARK V

1095/1595 Premium Hi

ti15036a

ti15034a

ti15035a

ti14838a

ENG

Содержание ti14838a

Страница 1: ...ints 3300 psi 227 bar 22 7 MPa Maximum Working Pressure IMPORTANT SAFETY INSTRUCTIONS Read all warnings and instructions in this manual Save these instructions Related Manuals Repair 3A0157 Parts 3A0158 Gun 311861 695 795 Premium Hi 695 795 MARK V 1095 1595 Premium Hi ti15036a ti15034a ti15035a ti14838a ENG ...

Страница 2: ...QuikReel Hi Boy Lo Boy 258723 258724 258878 258879 258881 258882 826128 826129 1095 ULTRA MAX III Model QuikReel Hi Boy Lo Boy 258727 258728 258883 258884 258886 826130 826131 1595 ULTRA MAX III Model QuikReel Hi Boy Lo Boy 258763 258764 258765 258766 826132 826133 826134 826135 MARK IV Model QuikReel Hi Boy Lo Boy 258729 MARK V Model QuikReel Hi Boy Lo Boy 258730 258887 ...

Страница 3: ...operly installed and grounded in accordance with all local codes and ordinances Improper installation of the grounding plug is able to result in a risk of electric shock When repair or replacement of the cord or plug is required do not connect the grounding wire to either flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the ground...

Страница 4: ...le materials Know the contents of the paints and solvents being sprayed Read all Material Safety Data Sheets MSDS and container labels provided with the paints and solvents Follow the paint and solvents manu facturer s safety instructions Fire extinguisher equipment shall be present and working Sprayer generates sparks When flammable liquid is used in or near the sprayer or for flushing or clean i...

Страница 5: ...ne by a qualified electrician and comply with all local codes and regula tions PRESSURIZED ALUMINUM PARTS HAZARD Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical reaction and equipment rupture Failure to follow this warning can result in death serious injury or property damage Do not use 1 1 1 trichloroethane methylene chloride other halogenated...

Страница 6: ...6 7 8 9 3 ti14839a 1 Premium Digital Display 2 ON OFF Switch 3 WatchDog Switch not available on Mark V or Standard Units 4 Pressure Control 5 Prime Spray Valve 6 Filter 7 Siphon Tube 8 Pump 9 Bearing Housing ProConnect 10 Drain Tube 11 Trigger Lock 12 Model Serial Tag 13 Hose Reel ...

Страница 7: ...uirements 100 120V units require 100 120 VAC 50 60 Hz 15A 1 phase 230V units require 230 VAC 50 60 HZ 10A 1 phase Extension Cord Use an extension cord with an undamaged ground con tact If an extension cord is necessary use a 3 wire 12 AWG 2 5 mm2 minimum Pails Solvent and oil based fluids follow local code Use only conductive metal pails placed on a grounded sur face such as concrete Do not place ...

Страница 8: ...ircuit rating Pressure Relief Procedure 1 Turn power OFF Wait 7 seconds for power to dissipate 2 Lock gun trigger safety Remove guard and SwitchTip 3 Turn pressure to lowest setting Trigger gun to relieve pressure 4 Put drain tube in pail Turn prime valve down to DRAIN position 20 ti14919a ti4265a ti10166a ti2769a ti14841a ti2595a ti14842a ...

Страница 9: ...ear Do this each time you spray 7 Turn power OFF 8 Plug power supply cord into a properly grounded electrical outlet 9 Turn prime valve down to DRAIN position 10 Place pump in grounded metal pail partially filled with flushing fluid Attach ground wire to pail and to true earth ground Perform steps 1 5 of Startup to flush out storage oil shipped in sprayer Use water to flush water base paint and mi...

Страница 10: ...gun and increase fluid pressure 1 2 turn Flush 1 minute 6 Inspect for leaks Do not stop leaks with hand or a rag If leaks occur perform Pressure Relief Proce dure page 8 Tighten fittings Perform Startup steps 1 5 If no leaks proceed to step 7 7 Place pump in paint pail 8 Trigger gun again into flushing pail until paint appears Move gun to paint pail and trigger for 20 seconds Set gun safety ON Ass...

Страница 11: ...vy edges 2 Hold gun perpendicular 10 12 in 25 30 cm from surface Spray back and forth Overlap by 50 Trig ger gun after moving and release before stopping Clearing Tip Clog 1 Release trigger put safety ON Rotate SwitchTip Take safety OFF Trigger gun to clear clog Never point gun at your hand or into a rag 2 Put safety ON Return SwitchTip to original position Take safety OFF and continue spraying ti...

Страница 12: ...on system detects an empty material pail 3 Turn WatchDog switch OFF Add material or reprime sprayer Turn pump switch OFF and ON to reset WatchDog protection system Turn WatchDog switch back ON to continue to monitor material level Fast Flush To flush the hose and gun at an accelerated speed per form the following steps 1 Perform steps 1 3 of Cleanup page 16 2 Hold gun trigger in and turn prime val...

Страница 13: ...Lift and turn pivot lock 90 to unlock hose reel Pull on hose to remove it from hose reel 3 Pull reel handle up and turn clockwise to reel in hose NOTE The hose reel can be locked into two positions Usage A and Storage B Be sure to keep your head clear of hose reel while winding up hose ti13504a ti13501a ti13503a ti13502a A B ti13563a ...

Страница 14: ...ressure units psi bar MPa to desired units Selec tion of bar or MPa changes gallons to liters x 10 To change display units DTS must be in pressure display mode and pressure must be at zero Job Gallons 1 Short press DTS button to move to Job Gallons or liters x 10 NOTE JOB scrolls past then the number of gallons sprayed above 1000 psi 70 bar 7 MPa displays 2 Press and hold to reset to zero Lifetime...

Страница 15: ...utton to clear error code to zero 7 Short press DTS button W DOG scrolls past then OFF displays if watchdog switch is OFF ON dis plays if Watchdog switch is ON 8 Press and hold 8 seconds DTS button to move to WatchDog Trigger menu Continue to hold DTS button and Watchdog can be set to trigger at 30 40 50 or 60 of current sprayer pressure setting Release DTS button when desired is displayed Default...

Страница 16: ...sh ing fluid appears 4 Move gun to waste pail hold gun against pail trig ger gun to thoroughly flush system Release trigger and put trigger safety ON 5 Turn prime valve down to DRAIN position and allow flushing fluid to circulate until flushing fluid appears clear 6 Turn prime valve forward to SPRAY position Trigger gun into flushing pail to purge fluid from hose 7 Raise siphon tube above flushing...

Страница 17: ... and inspect Install filters 10 If flushing with water flush again with mineral spirits or Pump Armor to leave a protective coating to pre vent freezing or corrosion 11 Wipe sprayer hose and gun with a rag soaked in water or mineral spirits ti15018a ti2895a Pump Armor ti2776a ...

Страница 18: ...Mark V N A 10 50 60 5000 2 4 1790 110 29 1 3 4 9 0 037 3 8 in 1595 20 15 50 60 N A 5000 2 8 2090 110 29 1 35 5 1 0 039 1 4 in Mark V 20 15 50 60 N A 5000 2 8 2090 110 29 1 35 5 1 0 039 3 8 in Model Weight lb kg Height in cm Length in cm Width in cm Lo Boy Hi Boy QuikReel Lo Boy Hi Boy QuikReel Lo Boy Hi Boy QuikReel 695 94 43 94 43 111 50 27 5 69 9 28 5 72 4 Handle down 38 75 98 4 Handle up 39 99 ...

Страница 19: ...Notes 3A0156A 19 Notes ...

Страница 20: ... in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of wa...