Operation
RD 12A
48
wc_tx001071gb.fm
4.26 Water Spray System
See Graphic: wc_gr002946, wc_gr003638
Water from the tank is fed to the spray bars by an electric pump. The
flow of the water is controlled by a switch and a rotary dial.
Press the upper half of the water spray switch
(61)
to turn the water
pump on. Turn the water spray dial
(62)
clockwise to increase the
spray frequency. Turn the water spray dial counter-clockwise to
decrease the spray frequency. Press the lower half of the water spray
switch
(61)
to turn the water pump off.
Only use clean water. Dirty water, even when filtered, will rapidly clog
the tubes of the spraying equipment.
During winter, or when temperatures drop to below 0°C (32°F), drain
the water tank and spraying equipment. Run the water pump to
remove excess water from the system. Drain the water through the
water drain plug
(41)
located near the bottom of the rear frame,
through the sprayer end plugs, and the water filter. Freezing water may
cause broken hoses, filters and water pumps and may deform the
water tank.
wc_gr003638
62
61
Содержание RD 12A
Страница 1: ...0182863en 001 0610 0 1 8 2 8 6 3 E N Operator s Manual Roller RD 12A...
Страница 8: ...Table of Contents RD 12A 8 wc_bo0182863en_001TOC fm...
Страница 16: ...Labels RD 12A 16 wc_si000302gb fm 2 Labels 2 1 Label Locations X FF GG GG...
Страница 23: ...RD 12A Lifting and Transporting wc_tx001556gb fm 23 Notes...
Страница 40: ...Operation RD 12A 40 wc_tx001071gb fm wc_gr002951 N F R 55 42 44 54 10 15...
Страница 74: ...Schematics RD 12A 74 Notes...
Страница 104: ...KE40246P1 6 9 05 3 14 PM Page 1...
Страница 105: ......