![Wacker Neuson GV 2500A Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/wacker-neuson/gv-2500a/gv-2500a_repair-manual_3169784036.webp)
Troubleshooting Voltage Issues
GV Generators
wc_tx000772gb.fm
36
Continued from the previous page.
17.Measure the voltage between the red (R) wire of the auto idle unit and the
white-black (W/B) wire of the auto idle unit.
Is at least 9.8VDC measured?
18.Place the main breaker in the ON position.
19.Connect a load to the generator.
20.Once again, measure the voltage between the red (R) wire of the auto idle unit
and the white-black (W/B) wire of the auto idle unit.
Is at least approximately 0 (zero) VDC measured?
21.Reassemble the generator.
The procedure to check the auto idle circuitry is now complete.
Yes ____
No ____
Your reading
Continue.
The auto idle unit has failed. Call
Wacker Service.
Yes ____
No ____
Your reading
The auto idle circuit is OK.
The auto idle unit has failed. Call
Wacker Service.