Troubleshooting Voltage Issues
GV Generators
wc_tx000772gb.fm
22
2.5
Checking the Excitation Winding
Prerequisites
Generator shut down
Multimeter
Procedure
Follow the procedure below to check the excitation winding.
1. Remove the end cap
(a)
from the generator.
2. Disconnect the plug
(b)
which connects the excitation winding to the Automatic
Voltage Regulator (AVR).
3. Measure the resistance of the excitation winding by measuring across the two
yellow (Y) wires of the connector.
Is the correct resistance measured for your model?
This procedure continues on the next page.
Yes ____
No ____
Your reading
Continue.
The excitation winding has failed.
Replace the stator.