![Wacker Neuson GV 2500A Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/wacker-neuson/gv-2500a/gv-2500a_repair-manual_3169784025.webp)
GV Generators
Troubleshooting Voltage Issues
wc_tx000772gb.fm
25
Continued from the previous page.
5. Check the resistance between the brown (Br) wire of the wiring harness connec-
tor
(b)
and the ground stud
(x)
.
Is any resistance measured?
6. Disconnect the 6-wire connector
(c)
.
7. Check for continuity between the light green (LG) wire of the 6-wire connector
and the black (B) wire of the generator.
Does the wiring have continuity?
8. Check the resistance between the light green (LG) wire of the wiring harness 6-
wire connector
(c)
and the ground stud
(x)
.
Is any resistance measured?
9. Check for continuity between the red-white (R/W) wire of the 6-wire connector
and the red (R) wire of the generator.
Does the wiring have continuity?
This procedure continues on the next page.
Yes ____
No ____
The sensing wire has failed. Replace the stator.
Continue.
Yes ____
No ____
Continue.
The wiring has failed. Replace the stator.
Yes ____
No ____
The sensing wire has failed. Replace the stator.
Continue.
Yes ____
No ____
Continue.
The wiring has failed. Replace the stator.