Troubleshooting Voltage Issues
GV Generators
wc_tx000772gb.fm
16
2.1
Charging the Generator with 9-Volt Battery
Prerequisites
9-Volt battery
Multimeter
Procedure
Follow the procedure below to test charge the generator with a 9-Volt battery.
1. Remove the end cap
(a)
from the generator.
2. Disconnect the wiring at the connector to the automatic voltage regulator (AVR)
(b)
.
3. Disconnect the wiring to the brushes.
4. Connect a 9-Volt battery to the brushes—this is a polarity-sensitive connection
so be certain to connect battery positive to the positive brush.
5. Start the engine.
6. Measure the AC voltage between the red and yellow wires at the terminal strip.
Is 18–65 VAC measured?
The procedure to test charge the generator is now complete.
Disconnect the 9-Volt battery and continue troubleshooting.
Yes ____
No ____
Your reading
The AVR has failed, replace it.
Continue troubleshooting by
checking the stator windings.
wc_gr004395
V
1000
200
20
2
200m
F
V
A
V-
COM
9V
+
–